    • Sonics ultrasonic liquid processor
    • VCX750
    • Power output of 750W, standard transducer horn processing volume from 50ml to 500ml.
    • VCX750
    • Sonics ultrasonic liquid processor
    • Power output of 750W, standard transducer horn processing volume from 50ml to 500ml.
    SONICS VCX750 ultrasonic liquid processor can safely handle a variety of organic and inorganic materials from 250 μL up to 500 mL*. Typical applications include nanotechnology (production of nanoparticles and graphene dispersions), cell lysis, sample preparation, homogenization, ChIP assays, emulsification, deagglomeration and disaggregation, as well as applications in the field of sonochemical liquid processing.
    Product Introduction
    SONICS VCX750 Sonics ultrasonic liquid processor can safely handle a variety of organic and inorganic materials from 250 μL up to 500 mL*. Typical applications include nanotechnology (production of nanoparticles and graphene dispersions), cell lysis, sample preparation, homogenization, ChIP assays, emulsification, deagglomeration and disaggregation, as well as applications in the field of sonochemical liquid processing.


    Product Features
    ◆Energy monitor
    ◆Integrated temperature controller prevents sample overheating, monitors and controls sample processing temperature within the range of 1℃ to 100℃
    ◆Digital ammeter
    ◆Microprocessor and programmable based
    ◆10-hour process timer
    ◆Independent on/off pulse generator
    ◆Variable power output control


    Experimental Purpose
    1. To understand the basic principles of ultrasonic cell disruption
    2. To master the basic techniques of ultrasonic cell disruption


    Experimental Principle
    When strong ultrasound waves act on a solution, the cavitation phenomenon of bubble generation, growth, and rupture is involved, and the shock wave and shear force caused by the cavitation phenomenon can cause cell lysis.
    Materials and Reagents
    10ml of bacteria, beaker, crushed ice, 75% alcohol swab.


    Probe Selection  
    Probe Model and Size Cell Disruption Volume
    2mm 150ul-5ml
    3mm 250ul-10ml
    6mm 10ml-50ml
    13mm 50ml-500ml


    Technical Parameters  
    Model: VCX 750
    Frequency: 20KHz
    Power: 750W
    Standard Amplitude Bar: Φ13mm
    Standard Amplitude Bar Length: 136mm
    Overall Size of Amplitude Bar: 235 x 190 x 340 mm
    Material of Amplitude Bar: Ti-6Al-4V titanium alloy
    Processing Capacity of Standard Amplitude Bar: 50ml to 500ml
    Optional Amplitude Bar: Φ2mm,Φ6mm,Φ13mm
    Variable amplitude rod weight: 900g
    Variable amplitude rod cable length: 1.8m
    Duty cycle: 1-99%
    Power adjustment range: Continuously adjustable (20-750w)
    Gap time: 0.1-99.9s
    Temperature protection setting: Available, energy and temperature setpoint control (temperature probe needs to be purchased separately)
    Power amplitude display: Available
    Operating frequency range: Energy monitor digital wattmeter automatic tuning automatic amplitude compensation
    Operating time: Programmable microprocessor-based 10-hour timer 1-59 seconds independent/on/off pulse
    Ultrasonic time: From 1 second to 10 hours
    Operating mode: Gap/continuous
    Power supply: 220/110V 50Hz/60Hz or 117V, 50/60Hz if not otherwise specified
    Net weight: 6.8kg
    Main unit + transducer weight: 3680g
    Product List
    VCX750 Unit
    Host Machine Unit
    Toolbox set
    Power cord piece
    Soundproof box set
    Special Crushing Cup Piece
    Temperature sensor piece
    User manual copy
    Description
    1
    1
    1
    Optional
    Optional
    Optional
    1
    一区二区三区四区精品视频