<address id="9tv9j"></address>

    <form id="9tv9j"><th id="9tv9j"><progress id="9tv9j"></progress></th></form>

    <address id="9tv9j"><address id="9tv9j"><nobr id="9tv9j"></nobr></address></address><noframes id="9tv9j"><listing id="9tv9j"><listing id="9tv9j"></listing></listing><noframes id="9tv9j"><form id="9tv9j"><nobr id="9tv9j"></nobr></form>

    <form id="9tv9j"></form>
    • SONICS Handheld Ultrasonic Cell Disruptor
    • VCX130
    • Power of 130W, standard amplitude rod processing capacity from 10ml to 50ml.
    • VCX130
    • SONICS Handheld Ultrasonic Cell Disruptor
    • Power of 130W, standard amplitude rod processing capacity from 10ml to 50ml.
    SONICS handheld ultrasonic cell disruptor VCX130: a 130-watt ultrasonic liquid processor with a timer and a pulsar for safe processing of a wide range of organic and inorganic materials from 150 μL to 150 mL for small-batch applications. Typical applications include biotech and pharmaceutical processing, including mixing, dispersing, and sample preparation use.
    Product Introduction
    SONICS Handheld Ultrasonic Cell Disruptor VCX130: a 130-watt ultrasonic liquid processor with a timer and a pulsar for safe processing of a wide range of organic and inorganic materials from 150 µL to 150 mL for small-batch applications. Typical applications include biotech and pharmaceutical processing, including mixing, dispersing, and sample preparation use.


    Product Features
    ◆Energy monitor
    ◆1-59 second independent on/off pulse generator
    ◆Digital voltmeter
    ◆Elapsed time indicator
    ◆10-hour timer
    ◆Variable power output control


    Experimental Objectives
    1. Understand the basic principles of ultrasonic cell disruption.
    2. Master the basic techniques of ultrasonic cell disruption.


    Principle of Experiment
    When strong sound waves act on a solution, the cavitation phenomenon of bubble generation, growth, and rupture is related. The shock waves and shear forces caused by cavitation phenomenon cause cell lysis.
    Materials and Reagents
    10ml bacteria, beaker, crushed ice, 75% alcohol cotton ball.


    Probe Selection  
    Probe Model and Size Cell Disruption Capacity
    2mm 150ul-5ml
    3mm 250ul-10ml
    6mm 10ml-50ml


    Technical Parameters  
    Model: VCX 130
    Frequency: 20KHz
    Power: 130W
    Timing device: 1s-10hr
    Pulse excitation device: Off: Manual On: 1-59 seconds adjustable
    Inverter model: CV18
    Standard amplitude bar: Φ6mm
    Standard amplitude bar length: 113mm
    Overall size of amplitude bar: 115 x 250 x 320 mm
    Amplitude bar material: Titanium alloy Ti-6Al-4V
    Standard amplitude bar processing capacity: 10ml to 50ml
    Optional amplitude bar: Φ2mm, Φ6mm, Φ13mm
    Amplitude bar weight: 340g
    Amplitude bar cable length: 1.5m
    Duty cycle: 1-99%
    Power adjustment range: Continuously adjustable (20-130w)
    Temperature protection setting: /
    Power amplitude display: Yes
    Working frequency range: Energy monitor digital wattmeter automatic tuning and automatic amplitude compensation
    Working mode: Pulse/continuous
    Power supply: 220/110V 50Hz/60Hz or unless otherwise specified, the power requirement is sent at 117V, 50/60Hz
    Net weight: 3.2kg
    Main unit + transducer weight: 3340g
    Product List
    VCX130 Unit
    Host Machine Unit
    Toolbox set
    Power cord piece
    Soundproof box set
    Special Crushing Cup Piece
    User manual copy
    Description